IMAGEWORKS - ImageVet-DC Xray Unit

The ImageVet-DC unit offers outstanding image quality by means of a 12” embedded collimation and constant potential high frequency generator. Harmful, low-energy “soft” radiation (which is non-diagnostic), is almost completely eliminated. The light weight of the DC tubehead and 12 inch internal collimation provides stable positioning and exceptional X-Rays.

Enquire Now

Category:

Features

The DCR handheld wireless remote allows the unit to be programmed from anywhere within the operatory. Appropriate selections of kV and mA are automatically determined by tooth selection and patient size. Exposures may be manually increased or decreased as needed. Uninterrupted use during multiple exposures is possible due to a “Dynamic Duty Cycle” that controls tubehead heat making the DC superior in both functionality and safety.

The Image-Vet DC Features:

  • Superior image quality
  • Seamlessly compatible with the EVA-Vet® Digital Dental Imaging System
  • Includes the Customer Care Program

Precision imaging

The compact tube-head features a long internal collimation of the X-ray beam, achieving a default 12” (30 cm) source-to-skin distance, which allows for sharper images and vital diagnostic detail. Sharper images are obtained thanks to a 0.7 mm focal spot and the outstanding parallelism achieved via 12” (30 cm) embedded collimation.

Easy controls

The wireless control device, which can be attached to any available surface in the surgery, offers a full range of intuitive exposure scenarios designed to make correct X-ray acquisition a straightforward process.

Minimal Radiation

The constant potential high frequency X-ray generator together with the embedded 12” (30 cm) collimation increases X-ray parallelism, leading to better image quality and significantly lower X-ray dosage.

The control unit records the dose to which the patient is exposed in mGy*cm2.

The most appropriate combination of technical factors (kV, mA and exposure time) is automatically determined according to patient size and anatomic region of interest.

 

 

 

 

Generator DC: Constant potential, microprocessor controlled
Voltage (kVp) 60, 63, 65 kVp
Focal spot 0.7 mm, square, IEC 336
X-Ray field (at collimator tip) 55mm or 60 mm round
Total filtration 2.5 mm Al
Anode current (mA) 6, 7 mA
Operating frequency 145 KHz - 230 KHz self adjusting (175 KHz typical)
Exposure Time 0.010 – 1.000 sec, R10 and R20 scale
Focus to skin distance 30 cm /300 mm - (12”)
Line voltage 50/60 Hz, 115V ± 10% or 230V ± 15%
Duty cycle Self regulating, continuous operation up to 1s/60s
Weight44.1 Lbs, (20Kg)
Weight of Tube-head 11 Lbs, (5Kg)
Extension Arms Available in 3 lengths:
15.75” (400 mm)
23.6” (600 mm)
35.4” (900 mm)
Certifications CE 0051, cCSAus