Skip to main content

NEWTOM - GO 2D/3D CEPH - OPG/CBCT

NewTom’s latest release, the GO 2D/3D + Ceph, paves the way to a new level of diagnostic possibilities while offering the smallest footprint of any CBCT/OPG + Ceph unit in the world.

Designed for dental surgeries with limited space, the GO 2D/3D + Ceph is the most compact and powerful solution with over 25 different 2D imaging functions and a full range of CBCT FOV for dental applications.

Enquire Now

Category:

Product Description

Versatile and precise

The GO 2D/3D CEPH provides high quality images that meet a wide range of clinical diagnostic needs, all in one compact device. The platform prioritizes patient health by offering low exposure protocols and NewTom’s exclusive SafeBeam™ technology, which lets users adapt the dose to their actual diagnostic needs and the size of the examined anatomical area.

Excellent ergonomics and an adaptive alignment system ensure correct positioning of the patient and perfect focusing for clear, detailed images. A virtual control panel guides the operator through each stage of the examination. NNT is the technologically advanced software platform to manage, process, consult and share diagnostic images.

Outstanding technology

Thanks to CBCT technology – first introduced to the dental industry by NewTom – the GO 2D/3D CEPH provides high definition (80 μm) diagnostics data, obtained with just one scan to minimise X-ray exposure. The field of view is defined according to diagnostic requirements and ranges from a minimum of 6 x 6 cm to a maximum of 10 x 10 cm. 2D images are available with multiple advanced function protocols that let dentists obtain precise data. Once again, every precaution is taken to safeguard patient health, for example through smart collimation and fast scans.

Automatic and ergonomic

The GO 2D/3D CEPH has a single native 16-bit sensor that produces 2D and 3D images with thousands of grey levels. Image quality is ensured by advanced algorithms and protocols and through high-tech image sequencing. The high frequency, pulsed-emission generator adjusts exposure to obtain the best scans with a minimum dose. Moreover, the cephalometric exam collimation system is based on automatic movement of the turret, which rotates and lowers the sensor, creating an opening for the X-rays directed at the 2D sensor on the teleradiographic arm.

Complete connectivity

This unit allows for excellent connectivity and integration with the modern systems adopted by NewTom. The internal workflow as well as clinical and diagnostic activities become easier and more efficient.

 

  • Broad diagnostic potential – A combination of device versatility and NewTom solutions designed to meet every diagnostic need broaden the opportunities available to the surgery.
  • Accessible technology – Guided procedures and smart automatic features have made this sophisticated technology available to all.
  • Minimum X-ray dose – Dose functions and SafeBeam™ technology, which automatically adapts to the dose radiated to the patient, put patient safety above all else.
  • Maximum connectivity – Acquired X-ray images can easily be stored, exported and shared with specialist third party software.
Images2D3D
TypeComplete or partial adult and child panoramic*, QuickPAN Orthogonal Panoramic, MultiPAN, Dentition, Bitewing*, Frontal and Lateral (right and left) maxillary sinuses, Temporomandibular Joint (2 x Lateral + 2 x Frontal) open and closed mouth. AP-PA, LL Standard, Long, Quick, Carpal teleradiography.
Complete examination of the 2 arches in a single scan for adults and children (reduced collimation). Studies of the maxillary region with maxillary sinuses. Studies localized to region of interest.
Maximum resolution (MTF10) PAN: 5 LP/mm
CEPH: 3 LP/mm
Best quality: ≥ 2 LP/mm
Voxel 80 μm (minimum section thickness)
Field of view (mm)PAN: 210 (length) x 115 (height)
CEPH: 258 (length) x 194 (height)
PAN Child: 180 (length) x 100 (height)
Dentition: 140 (length) x 10 (height)
Bitewing: 167 (length) x 70 (height)
DENT and SIN: 100 (diameter) x 100 (height)
100 (diameter) x 70 (height)
100 (diameter) x 60 (height)
80 (diameter) x 70 (height)
80 (diameter) x 60 (height)
80 (diameter) x 100 (height)
60 (diameter) x 70 (height)
60 (diameter) x 60 (height)
Maximum image data dimensions PAN: 7.5 MB (single image)
CEPH: 14 MB
720 MB
MagnificationPAN 1.2 - 1.3
CEPH 1.13
1 to 1 (Isotropic voxel)
Scan time PAN: 13.8 s (ORTO), 12.3s (STD.), 6.8s (ECO)
CEPH: 9.9 s (STD); 3.7s (ECO)
BEST QUALITY: 16.8s (High Resolution)
REGULAR: 11.2s (Standard)
ECO: 6.4s (Low Dose)
Estimate of typical effective dose (ICRP 103)PAN: 5 - 9 μSvFOV: 10x10 | 35 μSv (Voxel 160 μm) - 80 μSv (Voxel 80 μm)
FOV: 6x6 | 9 μSv (Voxel 160 μm) - 27 μSv (Voxel 80 μm)
Minimum image display timesRealTime 15 s
Advanced filters aPAN (Auto adaptive PAN)
ApT (Autoadaptive Picture Treatments)
aMAR (Autoadaptive Metal Artifact Removal)
3D PAN & 3D Pan-Ceph 
Focal Spot 0.6 mm (IEC 60336)
Anode Voltage2D mode: 60 kV – 85 kV continuous emission
3D mode: 90 kV (Pulsed mode)
Inherent Filtration 2D > 2,5 mm Al eq. (at 85 kV)
3D 6 mm Al eq. (at 90 kV)
Generator Type Constant potential (DC)
Anode Current4 mA - 15 mA
Exposure ControlSafeBeamTM
Maximum Continuous Anode Input Power 42 W (1:20 at 85 kV/10 mA)
Embedded X-ray Shielding Behind ReceptorReceptor IEC60601-1-3 compliant
Detector
Function3D et PAN
CEPH
Type Amorphous Silicon (CSI)
CMOS (CsI)
Dynamic range 16bit (65,535 grey levels)
14bit (16,383 grey levels)
Ergonomics
Examination Selection Procedure guided from virtual control panel on PC and/or iPad
Patient Positioning Suggestion from virtual control panel - Servo-assisted alignment, 3 laser guides (3D Scout View)
Patient Positioning 5 contact point, adjustable 3D/2D version right/left
Adjustments2-speed height adjustment drive Keypad on machine and/or iPad app
Servo-assisted alignment: Keypad on machine or remote control (via Scout View)
Other FunctionsMultilingual, parking position, remote control
NotesEasy access for patients in wheelchairs
Connectivity
ConnectionsLAN / Ethernet
Software NewTom NNT and App iPad NNTviewer (Free)
Supported Protocols DICOM 3.0, TWAIN, VDDS
DICOM NodesIHE compliant (Print; Storage Commitment; WorkList MPPS; Query Retrieve)
App iPad Virtual control panel for the device and the NNT 2D viewer
Installation
Minimum Space Requirement (L x D) CEPH version: 1785 mm x 1030 mm
Package Dimensions (L) x (P) x (H) in mm
Box1: 930 x 690 x 960 (Machine Base)
Box2: 1860 x 355 x 350 (Column on the ground)
Box3: 575 x 1275 x 380 (Teleradiographic Arm)
Weight 3D/2D version: 93.5 Kg (251 lb) + CEPH: 21 kg (46 lb)
Accessories Free standing base
Power Supply
Voltage | Frequency 115 – 240 V single-phase | 50 / 60 Hz
Maximum Absorbed Surge Current20 A at 115 V; 12 A at 240 V
Current Absorption in Standby Mode Maximum 0.5 A (240 V); 1 A (115 V)
NotesAutomatic adaptation for voltage and frequency
Manufacturers

Cefla, NewTom

Categories

,