Unrivalled HyperSphere technology places this high-frequency X-ray unit in a class of its own for ergonomics, wireless convenience and image clarity. Specifically conceived for digital X-ray imaging, the constant potential tube head combined with the smallest focal spot available for intraoral imaging (0.4 mm) guarantees consistently sharp images and exceptional X-rays.

The DCR handheld wireless remote allows the unit to be programmed from anywhere within the operatory. Appropriate selections of kV and mA are automatically determined by tooth selection and patient size. Exposures may be manually increased or decreased as needed. Uninterrupted use during multiple exposures is possible due to a “Dynamic Duty Cycle” that controls tubehead heat making the DC superior in both functionality and safety.

Revolutionary positioning device

Able to revolve freely around the sphere, the lightweight, compact tube head reaches practically any position, including vertical. The full-swivel ball-joint is revolutionary in every sense.
For effortless repositioning of the tube head between exposures the RXDC HyperSphere+ has an automatic touch-sensitive lock-on/lock-off device. By simply touching the touch-sensitive zones the tube head is unlocked for quick and easy positioning. As soon as you let go, the tube head locks into place with great precision.

Simple wireless control

To acquire excellent images the handheld wireless digital control device can be attached to any available surface in the surgery. It offers a full range of intuitive exposure scenarios designed to make correct X-ray acquisition a straightforward process. Simply by selecting the region of interest, RXDC HyperSphere+ automatically defines the correct exposure. There are no other wall-mounted or wired control panels to worry about.

Minimal radiation

The constant potential high frequency X-ray generator together with the embedded 12’’ rectangular collimator increases X-ray parallelism, leading to better image quality and significantly lower X-ray dosage compared to traditional X-ray units. The control unit records the dose to which the patient is exposed in mGy*cm2.
The most appropriate combination of technical factors (kV, mA and exposure time) is automatically determined according to patient size and anatomic region of interest.

StandardsClass 1 type B (EN 60601-1)
Power supply115 - 230V at 50-60 Hz
HF generator60, 63, 65 kV; 6.7 mA constant potential
Focal spot size0.4 mm (IEC 336)
Total filtration2.5mm AL
Duty CycleSelf regulating, continuous operation up to 1s/60s
StabilityAutomatic touch-sensitive lock-on/lock-off (HyperSphere)
Exposure timeFrom 0.010 to 1.000 sec
Distance focal spot to skin30 and 20 cm round, 30 cm rectangular
Circular collimator35 x 45 mm rectangular, 55 mm or 60 mm diameter round
Additional collimators31 x 41 mm and 22 x 35 mm rectangular
Extension arm40, 60, and 90 cm

ISO9001 Quality Certified: Inline Systems is committed to providing professional and superior service.

ISO9001 Quality Certified
Inline Systems is committed to providing professional and superior service.